Design of Anti-fumigation Wall Heating

2018-06-20 Environmental design 2571 11 11

Jessie

China · Home Furniture

Design of Anti-fumigation Wall Heating

2018-06-20 Environmental design 2571 11 11

Jessie

China · Home Furniture
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
New products of St. Lawrence radiator in 2017,
11 2
Users’ other works View More
Comment

Comment Board (11)

-滴哒哆 2018-10-10
Reply

I just want to ask if it will be very hot when I accidentally touch this thing at work. Because I haven't used it

JessieOwner 2018-10-10
Reply
Not at all, not hot. Northerners use a lot of people. The cast iron heating used a long time ago is hot to the touch. This is a pure copper water pipe in the middle, which is a heat transfer body. The panel is aluminum and is a heat sink. Therefore, there is a certain distance between the panel and the water pipe and it will not be hot. However, due to the characteristics of the material, it cannot be said that the heat dissipation of, at present, this material has the highest cost and the best heat dissipation in the heating industry.
-滴哒哆 2018-10-10
Reply
Oh, oh, thank you, popular science
战锷 2018-10-11
Reply
The northerners used geothermal heat.
JessieOwner 2018-10-11
Reply
Geothermal is indeed very common, but it has not completely replaced plumbing, and the sales volume of plumbing is still quite large.
Write a comment
李洪刚 2018-06-24
Reply

Jessie, from the cross section, why is there a triangular space between the hot column and the radiator? Is it necessary for appearance?

JessieOwner 2018-06-24
Reply
This approach has an intention, not that the appearance needs to be more accurate but that the function needs. With this triangular turning surface, more space can be left at the top and bottom of the heating, allowing more gas to come in from the bottom and go out from the top to enhance the convection effect of the gas, that is, the more air you enter, the stronger the convection effect, the better the heat dissipation of the heating.
Write a comment
我有只猫叫啊丑 2018-06-21
Reply

Southerners never thought there was such a thing.

JessieOwner 2018-06-21
Reply
Ha, ha, ha, yes, but some areas in the south are quite cold in winter and can only use air conditioning, which is more comfortable and less dry than air conditioning.
Write a comment
凡凡 2018-06-20
Reply

Do you still need to open the screw to drain water between heating and cooling?

JessieOwner 2018-06-20
Reply
Steel heating needs full water maintenance to prevent oxidation after stopping heating. Copper-aluminum composite heating does not matter. When heating again in the coming year, the residential property will inform everyone to test the water. Without adding, it is only necessary to open the valve, so there is no need to drain water midway.